Some shingle manufacturers require ice and water shield on very low sloped decks between 2 12 and 4 12.
Low slope metal roof underlayment.
The other side is 2 12.
Lower slopes for low slope standing seam metal roof applications strictly peel and stick underlayment is a better choice.
Structural metal panel roof systems can be used for low slope roofs because of their hydrostatic or water barrier characteristics.
The membrane will outlast the shingles and seal around all nail penetrations.
For a low slope residential roof there are two main options.
Then apply standard asphalt shingles over the membrane.
Ft model 5003002.
Roll self adhered roofing underlayment 225 sq.
Low slope metal roofs require less material which reduces the overall load on the building s structure.
Determining which panel is the right choice for the slope on your project will depend on the manufacturer s minimum slope factor for that specific panel profile.
My roof at lowest is 75 12.
Asphalt saturated felt along the eaves and lap succeeding courses by 19 inches as shown in figure 2 3.
Ft coverage sbs modified asphalt polyester self adhered low slope roofing roll in black model lb323235.
Low slope metal roofs have simple geometries and are easier and less expensive to install that medium to steep slope roofs.
At sheffield metals we also recognize low slope as 3 12 and below.
Once the high temperature ice and water shield has been laid down you can now add the second underlayment layer.
1 cover the entire surface with a self adhesive flashing membrane such as grace ice water shield there are many equivalent products.
There is only one category of metal roof systems used in low slope applications structural metal panel.
A metal roof mechanically seamed crimped and butyl injected at the seams designed to handle low slopes as low as 5 12.
Asphalt shingles can be used on roofs with a slope of 2 12 to 4 12 if double coverage underlayment is used.
Start with a 19 inch strip of 15 lb.
Low slope roofs are not totally flat their roof slope generally ranges from 1 4 12 to 3 12.
Guide to roofing underlayment installation on low slope roofs with asphalt shingles.
Minimum metal roof slope depends on the roof profile building design climate and site location.
These advantages and disadvantages do not apply to granulated synthetic underlayment as it is not to be used directly under metal roofing.
In fact many synthetic underlayments are designed for specific roofing materials so be sure to check and verify beforehand.
A low slope roof is defined in the industry as a roof that has a pitch equal to 3 12 or less.
If the roof slope is below 3 12 pitch see our previous post on how to determine a roof s pitch the entire roof should be covered but only if the roof is conventionally vented cold roof construction.